Network based, graceful, unattended shutdown of your physical servers and virtual machines protects data integrity and reduces system downtime when critical events such as. How to restart machines after ups regains power, but. Enables ease of configuration and ensures it equipment is protected as quickly as possiblesecure communications. Ups network management cards remote monitoring and control of an individual ups by connecting it directly to the network. Powerchute business edition ups management, graceful shutdown, and energy management software for servers and workstations using dedicated serial or usb connections. How to set ip address ap9617 apc network management card. Netflow traffic analyzer nta network configuration. Powerchute network shutdown documents and downloads. Solved apc virtual appliance and esxesxi utilities. Cyberpower offers free power management software with compatible uninterruptible power supply ups systems to monitor and control your ups. If the ip address on the ups changes, is there a way to change the ip address in pcns other than unstalling and reinstalling the pncs software.
For ease of access, you can use the link below to download the software based on their respective operating system. Shutdown for windows parallel silcon configuration. Powerchute network shutdown works in conjunction with the apc ups network management card to protect your physical and virtual it environment from threats to it availability. Powerchute network shutdown will always shut your servers down when low battery signal time is reached.
Powerchute business edition documents and downloads. Powerchutetm network shutdown powerchute works in conjunction with the ups. Installing apc ups powerchute network shutdown software on. Learn how to do the apc ups powerchute network shutdown installation. Run command file on network shutdown sequence as well as.
Schneider electric as standards, specifications, and design. Configuration intuitive navigation to confirm, exit or adjust settings escape, return and navigation buttons. The device ip configuration utility only supports the discovery of unassigned. Now, you need to access the apc website and download the software named. The apc configuration tool is available at the apc website. Installation guide installing on windows and windows server core follow these steps below. Powerchute network shutdown now only displays supported ups events in the. Looking for advice on how to install and configure apc powerchute network shutdown on my esxi servers so that they can be shut down gracefully upon power failure. The apc powerchute network shutdown apc client software was installed on the pc running the avaya. Locate the powerchute installation executable file, setupx32. I usually setup the network card and shutdown utility on each individual vm, but it would be nice to know the host would. All, the pncs software on the client needs to know the ip address of the ups. To start powerchute network shutdown manually, type the following at the command line. Solved installconfigure apc powerchute on esxi ups.
I want to shut down all the servers linux and windows connected to our apc smartups, which is easily done with powerchute network shutdown, and then restart them once power is restored to the ups, which is very easy if the ups is fully drained and shuts down. Apc network management utility download monthlywretched. Also, on the ups web ui, under configuration, under outlet groups for the pc outlet, i left the defaults. Ipv6 initial setup ipv6 network configuration provides flexibility to accommodate your requirements. The device ip configuration utility only supports the discovery of unassigned devices.
Download apc ip configuration wizard for free windows. Whether youd like to monitor a single ups or help with managing your entire virtualized network, eaton has a monitoring and management software solution. Save utility costs and reduces heat promoting longer componentlife. The reset button resets the network management card, so youll lose all of your settings if you do that. Energy cost and co 2 reporting provides greater understanding of the energy.
Installing apc ups powerchute network shutdown software on vmware vsphere management assistant for use with vmware esxi hosts walkthrough guide. Installing powerchute business edition agent on windows. A walkthrough guide for installing apc powerchute for virtualization on a raspberry pie 3 running suse sles to monitor your ups for a controlled shutdown. Software downloads page on the apc web site and select powerchute network shutdown.
The downloaded file will be named something like pcns300esxi. Installing powerchute network shutdown v4 on windows youtube. Powerchute network shutdown lost communications or cannot establish communication with ups. Powerchute network shutdown edition software provides ups management, safe system shutdown, and innovative energy.
Network management card 2 user guide schneider electric. Device ip configuration utility configure the basic settings of one or more nmcs over the network, see device ip configuration utility. Download documents for ups network management cards remote monitoring and control of an individual ups by connecting it directly to the network. How to configure apc powerchute network shutdown for. Browse products from schneider electric ww in for powerchute network shutdown reliable network based shutdown of multiple servers.
The problem is that we dont know the ip address that the aps ups got from the dhcp server. Configuration of apc powerchute network shutdown october 20, 2010 february 6, 2014 tradosh in order to correctly shutdown all the servers after you install the ups and software you need to make sure that you put the correct settings in. The apc ups will receive an ip address automatically from the dhcp server. Installing powerchute network shutdown v4 on windows schneider electric. Tutorial apc ups initial ip address configuration step. Powerchute business edition software provides ups management, graceful shutdown and innovative energy management capabilities. Now that we have configure the network monitoring card, its time to configure the servers. Reliable networkbased shutdown of multiple servers. Ups network management cards documents and downloads. Its been several years since ive used an apc network management card, but iirc you need to install the powerchute network shutdown configuration utility on your servers and configure it to communicate with the apc unit.
As for your query, if you are looking for the software to gracefully shutdown the servercomputer, this is the powerchute network shutdown software. The model number is not on the front of the unit, but can be found on a sticker on either the bottom or rear of your product. Tutorial for installing powerchute network shutdown v4 on microsoft windows to. The powerchute network shutdown configuration screen in the web ui has a dropdown box which allows you to choose the protocol used to communicate with powerchute. Rating is available when the video has been rented. Network management device ip configuration wizard 5. Install the network management card nmc in your ups and configure it with.
Electrical car charging electrical protection and control emergency lighting home automation. Powerchute network shutdown provide unattended remote graceful shutdown of computers that are connected to ups devices. Download the powerchute network shutdown for esxi from the most current version at the time of writing this is v3. In a redundantups configuration, powerchute network shutdown recognizes a group of either two or three upss as a single ups. From monitoring event history, notifying you of alerts and delivering realtime. So when the power is restored to the ups, will the outlet group turn back on restoring power to the pc. I know win7 does not have the ups utility that was available in earlier versions of windows, but what are the limits compared to powerchute if i use the power profile capability in win7 for my usb connected smartups. Tutorial apc ups powerchute network shutdown installation on. In this configuration, one powerchute network shutdown agent on a server communicates with two or three nmcs depending on the number of upss in. The chosen protocol must be enabled on your device before powerchute communications can be established. For detailed information on how to use a dhcp server to configure the tcpip settings at an nmc, see dhcp response options. Download apc ip configuration utility for free windows. It can be adjusted higher if you need more than two minutes to complete.
Application notes for avaya ip office and american power. Powerchute clients add the ip addresses of the servers you are going to gracefully shut down. Configure apc smart ups to shutdown servers spiceworks. You need to see how long your run time is, and make sure the shut down configuration actually works. To install and operate the powerchute network shutdown software, perform the following steps first. Download and install pcns on the physical servers you plan to gracefully shut down in the event of a power outage. Powerchute network shutdown lost communications or cannot. The wizard is available as a free download from the apc website at.
1462 1174 1291 186 574 1255 1168 1306 1152 1028 1132 141 462 1184 823 1552 453 684 1340 678 605 690 740 1424 941 1416 202 425 678 952 320 929 214 1099 1295 951 3 312 285 621 31